General Water Wizard Gantry and Pump Stand Maintenance/Service Tips:

  1. Check all eyes for any visible damage and make sure they are clean. Use your eye tester and cable to check the reading on both gantry and safety eyes (AW A14 is the best and G2 is unacceptable).
  2. Check all seven proxs to be sure they are clean on the end and have a gap of 3/16”. Use dielectric grease in the connections of all proxs and eyes.
  3. Check all chemical pumps for leaks and correct pressure. Make sure all air regulators are set correctly.
    a. Pre-soak pump at 50lbs and air at 30lbs
    b. Tire Cleaner pump at 50lbs and air at 30lbs
    c. Triple Shine pump at 50lbs and air at 45lbs
  4. Pre-Soak heater should not be over 120ºF.
  5. The wash boom in the gantry must be level with the frame. Both rubber bump stops, in the frame, on the passenger side of the boom must be in place.
  6. Do not put grease on the vertical guide rods in the gantry. Keep them free of dust and dirt.
  7. Do a visual check of all parts of the pump stand and gantry to be sure nothing is leaking and everything is working properly. If anything looks out of the ordinary, investigate further.

If none of these tips help solve the problem, contact our Automatic Technical Support Department for further troubleshooting. They can be reached at 1-800-999-9878.

  water wizard video | standard features | additional performance options | built tough | total operator control | site designs |
custom graphics | typical layout | service tips
 videos | Fusion X | water wizard 2.0 | swipe @ the bay | self-service equipment | money manager | entry wizard 2.0 | in-bay services
swipe-n-clean | vacuums | vending | bill changers | meters and vaults | awnings | promotional | product manuals | engineering
  movies | about JCC | products | news | photos | FREE literature | parts manuals | contact JCC/Hanna | site map | blog | tunnel wash