SERVICE
TIPS
General
Water Wizard Gantry and Pump Stand
Maintenance/Service Tips:
- Check
all eyes for any visible damage
and make sure they are clean. Use
your eye tester and cable to check
the reading on both gantry and safety
eyes (AW A14 is the best and G2
is unacceptable).
-
Check all seven proxs to be sure
they are clean on the end and have
a gap of 3/16”. Use dielectric
grease in the connections of all
proxs and eyes.
-
Check all chemical pumps for leaks
and correct pressure. Make sure
all air regulators are set correctly.
a. Pre-soak pump at 50lbs and air
at 30lbs
b. Tire Cleaner pump at 50lbs and
air at 30lbs
c. Triple Shine pump at 50lbs and
air at 45lbs
-
Pre-Soak heater should not be over
120ºF.
-
The wash boom in the gantry must
be level with the frame. Both rubber
bump stops, in the frame, on the
passenger side of the boom must
be in place.
-
Do not put grease on the vertical
guide rods in the gantry. Keep them
free of dust and dirt.
-
Do a visual check of all parts of
the pump stand and gantry to be
sure nothing is leaking and everything
is working properly. If anything
looks out of the ordinary, investigate
further.
If
none of these tips help solve the
problem, contact our Automatic Technical
Support Department for further troubleshooting.
They can be reached at 1-800-999-9878. |